Fire Rated Wall Box Installation

Designed for commercial and multi family applications these boxes are warnock hersey certified for 1 hour and 2 hour fire rated walls.
Fire rated wall box installation. If a 2 hour fire rated wall fails the 24 inch rule regulation during a fire inspection there are two simple products that can be easily installed to the outlets to pass the fire code. The pwb fr 450 is a larger capacity box that can accommodate crestron s dm rmc 4k scalar c receiver room controller or 3 ac outlets and 4 single gang compartments. Metacaulk cover guards are installed on the inside of the outlet cover plate and metacaulk box guards are installed on the inside back wall of the outlet. Fsr is expanding its popular pwb series wall boxes with the pwb fr 450.
This is an apartment building with rooms on each side of the firewalls and the spacing of receptacles is critical. Boxes in fire rated walls. 3105e157 series installation fire rated one and two hours 1. Use the actual wall box as a cut out template whilst referring to the table above for recommended cut out dimensions 3.
Wall boxes suitable for epic series module 2. Installation shall be in accordance with the published classification the manufacturer s instructions and applicable codes. The main purpose of this. The industry s only fire rated wall box.
In some classifications the surface area of the individual boxes may be increased from 16 sq in. Oatey fire rated washing machine outlet boxes can be used in all applications that require supply valves and waste drains recessed into a fire rated wall. Ceiling boxes and single. Recessed boxes in fire rated walls using firestop putty pads box inserts cover plate gaskets and endothermic mats by john valiulis ifc technical director a penetration that affects only one side of a rated wall is referred to as a membrane penetration.
Oatey products have earned the trust of plumbing professionals for over 100 years. Download our white paper on the pwb fr 450. Carlon s wall boxes may be used in both 2 and 1 hour fire rated wall assemblies. Fire rated outlet box spacing the electrical inspector says that i cannot install receptacles in fire rated walls closer than 24 inches back to back.
When wall opening protective materials are used. Such penetrations occur most frequently due to the installation of recessed electrical boxes. Before the boxes can be used in a fire rated wall or floor ceiling assembly the assembly must be tested with the boxes installed to determine if these combustible materials will compromise the current fire ratings of these systems.