Fire Sprinkler Riser Room Location

If the fire service lead in is more than 100 f t in total length the assembly.
Fire sprinkler riser room location. A system s risers may be in a hallway or on the outside of a building. Automatic sprinkler system risers fire pumps and controllers shall be provided with ready access. Where lo cated in a fire pump room or automatic sprinkler system riser room the door shall be permitted to be locked provided the key is available at all. Neither the nfpa nor the icc international code council requires that a proper riser room be provided for a fire sprinkler system s risers.
Then it conveys that water to the network of pipes running to fire sprinkler heads. Automatic sprinkler systems. Automatic sprinkler systems 903 2 11 1 1 opening dimensions and access. 2 rooms housing the control valves and sprinkler riser s shall be located in such a manner as to allow the door to exit directly to the outside of the structure and be a separate and distinct room.
Risers and components that typically attach to them are essential to normal sprinkler system operations including. Location of fire riser. Such openings shall be accessible to the fire department from the exterior and shall not be obstructed in a manner that fire fighting or rescue cannot be accomplished from the exterior. Thereafter the riser goes to floor 1 and above.
The municipal water enters the building and goes through the backflow preventer and then into the fire pump both being located in the fire pump room. Sprinkler riser rooms must be located on the ground floor with a door that s directly accessible from the outside. Mckinney fire department fire marshal s office automatic fire sprinkler system s 2200 taylor burk mckinney tx 75071 page 3 of 5 be located within the riser room. The riser location will be dictated by nfpa 13 2010 edition section 10 6 1 and the jurisdiction s adopted fire code.
Openings shall have a minimum dimension of not less than 30 inches 762 mm. But fire code also gives property owners some leeway in determining their exact location within a building. Fire sprinkler risers are in a sense where the plumbing outside a building ends and a fire sprinkler system begins. On the first floor there is a floor control valve with drain.
Tomatic sprinkler system riser rooms and fire pump rooms. The room shall not be used for the storage of any material. Each riser taps into a permanent source of water such as a pipe connected to the city water system a water tank or reservoir. 2018 code 901 4 6 4 901 4 6 1 access.